Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
18650 Battery Capacity Discharge Tester 6 Single NiMH Cell Echelon Utilization Recovery

18650 Battery Capacity Discharge Tester 6 Single NiMH Cell Echelon Utilization Recovery

  • High Light

    18650 Battery Capacity Discharge Tester

    ,

    NiMH Cell Battery Capacity Discharge Tester

    ,

    NiMH Cell 18650 discharge tester

  • Warranty
    1 Year
  • Voltage Range
    1.5V - 5V
  • Max Steps Per Loop
    255
  • Data Output
    EXCEL , Graph
  • Dimensions
    3U , 480mm – 330mm - 180mm
  • Channel Control Mode
    Independent
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008T-5V12A-S1
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Carton
  • Delivery Time
    8 work days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

18650 Battery Capacity Discharge Tester 6 Single NiMH Cell Echelon Utilization Recovery

Neware Battery Capacity Discharge Tester Echelon Utilization Battery Recovery

 

a . BTS4000 is very possibly the correct choice for you to get to know Neware and her battery test products better .

Till year 2017 , 90percent new customers of Neware would choose BTS4000 as a starting point , its really the time - proven and reliable choice .

 

b . Due to the rapid data acquisition frequency , BTS4000 could be applied to super capacitor or EDLC - Electronic Double Layer Capacitor test . Through our advanced software , the capacitance , DCIR - Direct Current Internal Resistance could be easily calculated .

 

c . Higher Accuracy . More Cost - effective . We believe it can improve your battery test .

 

d . Neware Battery Charge and Discharge Test System , ranging from uA single cell applications up to 1MW packs , is a high precision system designed specifically for testing lithium ion battery cells , modules , packs and capacitors . It is suitable for product development , quality control , and helpful to characteristic research , cycle life testing , product screening , and quality assessment .

 

Recycle Battery Function

 

a . If you have recovery battery pack , like Toyota Prius battery pack - generally , each piece has 6 single NiMH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter .


Voltage and Current - the Very Essential

 

b . The accuracies of Voltage and / or current may fundamentally affect the results come from a test . Thats why accuracies of voltage and current are so important to a battery tester .

 

c . Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .

 

d . A measurement system can be accurate but not precise , precise but not accurate , neither , or both . Neware battery testers provide good prrecision meanwhile . To get an overall performance of a measurement system , Measurement system analysis  MSA is usually introduced for the study .

 

Input Power 425W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range 1.5V - 5V
Accuracy 0.05 percent of FS
Current Per Channel Current Range Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A
Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Data Recording Record Condition Min Time - 100mS
Min Voltage - 10mV
  Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA
Record Frequency 10Hz
Pulse charge CCC , CPC
Discharge CCD , CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
Cycle Loop Measure Range 65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function , Max Support 3 Layers
Protection Software Protection Power - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
Per Unit Main Channels No. 8
Dimensions 3U , 480 – 330 - 180mm

 

18650 Battery Capacity Discharge Tester 6 Single NiMH Cell Echelon Utilization Recovery 0