Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
3 Electrodes Battery Cycler System Neware BTS4000 Charger Analyzer

3 Electrodes Battery Cycler System Neware BTS4000 Charger Analyzer

  • High Light

    bts4000 Battery Cycler System

    ,

    neware bts4000

    ,

    BTS4000 battery life analyzer

  • Charge Voltage
    0V - 5V
  • Current
    5uA - 20mA
  • Min Pulse Width
    500ms
  • Protection
    Upper Voltage Limit , Low Current Limit
  • Communication Interface
    Ethernet Port
  • Max Steps Per Loop
    Less Than 255
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008T-5V20mA-164
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Carton Box
  • Delivery Time
    8 working days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

3 Electrodes Battery Cycler System Neware BTS4000 Charger Analyzer

Neware 5V10MA Battery Cycler System Pulse DCIR 10HZ Data Recording Tester

 

The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc .

 

Neware 5V10mA / 20mA / 50mA is born for coin cell test , formerly its 5V1mA this modle . Students and researchers in universities and institutes just love this product , its the real star on their mind .

 

Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .

 

dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .

 

Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny current .

 

Testing with the uA current unit is more accurate and more convenient .

 

The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .

 

Voltage Per Channel Voltage Range 0V - 5V
Discharge Min Voltage 0V
Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Current Per Channel Current Range Range1 , 5uA – 1mA Range2 , 1mA – 10mA Range3 , 10mA – 20mA
Power Per Channel Output Power 0.25W
Stop current Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA
Stability 0.1percent of FS
Charge Charge Mode CCCharge , CVCharge , CCCVCharge , CPCharge
End Conditon Voltage , Current , Relative Time , Capacity , -deltaV
Discharge Discharge Mode CCD , CPD , CRD
End Condition Voltage , Current , Relative Time , Capacity
Pulse End Condition Voltage, Test Time
Cycle Loop Measure Range 65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function , Max Support 3 Layers
Protection Software Protection Power - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
IP protection level Protection level IP20
Voltage and Current Testing Sample 4 - wire connecting
Database MySQL Database
Per Unit Main Channels No. 8
Dimensions 3U , 480 – 404 - 130mm

 

3 Electrodes Battery Cycler System Neware BTS4000 Charger Analyzer 0