Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
3 Electrodes High Rate Discharge Cell Tester , 5V20mA Lithium Battery Testing Equipment

3 Electrodes High Rate Discharge Cell Tester , 5V20mA Lithium Battery Testing Equipment

  • High Light

    5V20mA lithium battery testing equipment

    ,

    3 Electrodes lithium battery testing equipment

    ,

    lithium high rate discharge cell tester

  • Voltage Range
    0V - 5V
  • Current Range
    5uA – 1mA 1mA – 10mA 10mA – 20mA
  • Current Response Time
    500uS
  • Pulse
    CC , CP
  • Input Power
    25W
  • Model
    CT-4008T-5V20mA-164
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008T-5V20mA-164
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Carton box , 530 - 360 - 130mm
  • Delivery Time
    8 working days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

3 Electrodes High Rate Discharge Cell Tester , 5V20mA Lithium Battery Testing Equipment

Neware 5V20mA Battery Cell Charger Three Electrodes Material Cycler

 

1 . Neware 5V10mA / 20mA / 50mA is born for coin cell test , formerly its 5V1mA this modle . Students and researchers in universities and institutes just love this product , its the real star on their mind .

 

2 . The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .

 

3 . The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc .

 

4 . Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .

 

5 . Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny current .

 

Data Recording Record Frequency 10Hz
Charge Charge Mode CCCharge , CVCharge , CCCVCharge , CPCharge
End Conditon Voltage , Current , Relative Time , Capacity , -deltaV
Discharge Discharge Mode CCD , CPD , CRD
End Condition Voltage , Current , Relative Time , Capacity
Pulse charge CCC , CPC
Discharge CCD , CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function , Max Support 3 Layers
Voltage and Current Testing Sample 4 - wire connecting
Database MySQL Database
A Means of Communication of Upper Machine TCP / IP Protocol
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 3U , 480 – 404 - 130mm

 

 3 Electrodes High Rate Discharge Cell Tester , 5V20mA Lithium Battery Testing Equipment 0