Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
Bidirectional 60V100A Regenerative Battery Pack Test System For Electric Vehicle

Bidirectional 60V100A Regenerative Battery Pack Test System For Electric Vehicle

  • High Light

    60V100A Regenerative Battery Pack Test System

    ,

    bidirectional electric car battery testing

    ,

    bidirectional Regenerative Battery Pack Test System

  • Voltage Range
    10V - 60V
  • Current Range
    0.5A - 100A
  • Precision
    Positive And Negative 0.02 Percent Of FS
  • Stability
    Positive And Negative 0.1 Percent Of FS
  • Current Response Time
    Less Than 3ms 10 Percent To 90 Percent
  • Cycles Times
    65535
  • Max Steps
    254
  • Database
    MySQL
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CE-6002-60V100A
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Wooden Box , W - D - H , 600 - 800 - 1800 mm
  • Delivery Time
    45 working days
  • Payment Terms
    T/T
  • Supply Ability
    50 Units Per Month

Bidirectional 60V100A Regenerative Battery Pack Test System For Electric Vehicle

Neware 60V100A Regenerative Battery Pack Tester of Electric Vehicle

 

CE - 6000 module pack testing system is a high - precision charging and discharging equipment specially developed for high - power battery pack testing . It has the characteristics of high dynamic response speed , high stability precision , multi - channel flexible configuration and so on . It supports pulse testing , cycle life testing and working condition simulation testing . The system has the function of multi - channel input and energy recovery , which can save a lot of electric energy consumed in the process of charging and discharging . Using bidirectional high - frequency DC converter topology and high - performance multi - channel 24 bit AD converter chip , the sampling resolution is higher than that of traditional single range equipment .

 

CE-6000 series battery testing system

Product introduction 

1 . Power battery simulation test, rate test .

2 . Cycle life test .

3 . Power, capacity and energy detection .

4 . Virtual configuration of power battery pack: charge and discharge curve fitting, battery consistency detection and evaluation;

5 . High rate charge and discharge ability detection .

6 . Power battery, energy storage battery series module detection: monomer voltage, monomer temperature monitoring - high voltage equipment .

 

Charge

Charge modes Constant current , Constant voltage , Constant current and voltage , Constant power
Cut - off condition Main channel - Voltage , Current , delta Time , Capacity , - delta V

Discharge

Discharge modes Constant current , Constant voltage , Constant power , Constant resistance
Cut - off condition Main channel - Voltage , Current , delta Time , Capacity

Pulse

Charge Constant current , Constant power
Discharge Constant current , Constant power
Min pulse width 100ms
Pulse counts Each pulse step supports 32 different pulses
Chg and Dschg switch Supported
Cut - off condition Voltage , Time
Simulated Condition Charge modes Constant current , Constant power
Discharge modes Constant current , Constant power
Cut - off condition Time , Line Number
Continuous switching Chg and Dischg One simulation step can realize a continuous switching from charging to discharging
Limit step number 1 million

Protection

Software protection

Power - off data protection
Off - line operation mode
User - defined protection conditions , such as upper and lower limited current / voltage , delay time , temperature , etc .
Charge and discharge efficifency more than 90 percent
Protection Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc.
Protection grade IP20
Channel parallel

supported , Parallel channels do not support pulse and simulation testing

Energy feedback The discharge energy can be fed back to the power grid
Channels feature Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channels control mode Independent control
Noise ≤65dB
Database MySQL
Communication TCP/IP
Operating system Windows 7/8/10 64bit
Data export EXCEL, TXT
Min. disk drive 500GB
Communication port Ethernet port

 