Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
CCD CPD CRD Discharge Lithium Battery Cycle Testing Equipment

CCD CPD CRD Discharge Lithium Battery Cycle Testing Equipment

  • High Light

    CCD Discharge Cycle Testing Equipment

    ,

    CPD Discharge Cycle Testing Equipment

    ,

    CCD Discharge Cycle Testing Machine

  • Discharge Min Voltage
    0V
  • Per Channel Voltage Range
    25mV - 5V
  • Per Channel Output Power
    30W
  • Per Channel Current Range
    0.5mA - 6A
  • Discharge Mode
    CCD . CPD . CRD
  • Software Protection
    Power-down Data Protection
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008Tn-5V6A-S1-F
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Carton box , 530 - 360 - 130mm
  • Delivery Time
    8 working days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

CCD CPD CRD Discharge Lithium Battery Cycle Testing Equipment

Regenerative Lithium Battery Cell Charge and Discharge Cylcer Testing Equipment

 

Neware CT-4008Tn-5V6A-S1-F is born for coin cell test , formerly its 5V3A this modle . Researchers in start up enterprise and institutes just love this product , its the real star on their mind .

 

1 . Testing with the uA current unit is more accurate and more convenient .

 

2 . This 8 Channels Coin Cell Analyzer 5V10mA provides most applications in battery testing fields such as electrode materials research, battery performance test , small - scale battery formation , capability grading , battery pack testing and etc .

20 set of mA Neware battery testers can be put in one rack

 

3 . CT-4000 Multi Range mA Battery Testing System , characterized with 0.05 percent of FS accuracy and down to uA capability , enables users to perform DCIR tests , dQ / dV and other basic tests on three - electrode system .

 

4 . It mainly focuses on battery research and development instituions and universities .

 

5 . dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .

 

resolution AD 16bit , DA 16bit
Voltage Per Channel Voltage Range 0V - 5V
Discharge Min Voltage 0V
Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Current Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Power Per Channel Output Power 0.25W
Stability 0.1percent of FS
Data Recording Record Condition Min Time - 100mS
Min Voltage - 10mV
Record Frequency 10Hz
Charge Charge Mode CCCharge , CVCharge , CCCVCharge , CPCharge
End Conditon Voltage , Current , Relative Time , Capacity , -deltaV
Discharge Discharge Mode CCD , CPD , CRD
End Condition Voltage , Current , Relative Time , Capacity
Pulse charge CCC , CPC
Discharge CCD , CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Voltage and Current Testing Sample 4 - wire connecting
Database MySQL Database
A Means of Communication of Upper Machine TCP / IP Protocol

 

 