Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
DCIR 18650 Battery Analyzer , Neware Rechargeable Battery Capacity Tester

DCIR 18650 Battery Analyzer , Neware Rechargeable Battery Capacity Tester

  • High Light

    DCIR 18650 battery analyzer

    ,

    Neware 18650 battery analyzer

    ,

    18650 rechargeable battery capacity tester

  • Precision
    0.05percent Of FS
  • Stable
    0.05percent Of FS
  • Current
    0.1A - 20A
  • Loop Measure Range
    65535
  • Record Frequency
    10Hz
  • Pulse Width
    500mS Above
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008-5V20A-A
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Wooden Box , 95cm - 62cm - 32cm , 30Kgs
  • Delivery Time
    8 working days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

DCIR 18650 Battery Analyzer , Neware Rechargeable Battery Capacity Tester

Neware 18650 Battery Rate Charge Discharge Capacity DCIR Tester


20ms Response Time
1 . This fast response time will meet rapidly changing power requirements

2 . Flexible Integration of Hardware and Data Management
3 . BTS 4000 functions also as the core part of auto formation and grading system .

4 . With its structural data system , testing data can be analysed , summarized , managed and utilized by our extended program or customers own data and logic server .

 

Accurate Timing

5 . Most of us are considering the voltage and current accuracies are the all important factors of a battery tester , but actually timing accuracy is of the same importance .

6 . Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated . To a general constant current or other constant testing regimes , this effect may not that easy to be observed .

7 . Left is from Neware , right is from another supplier in the marke .

 

Data Security

8 . Neware battery testing system utilizes LAN as the main framework to transfer data .

9 . This provides the most flexibility and reliablity to your system deployment .

10 . When you look down into Neware batter, its unique Middle Machine architecture provides another enhancement layer to the data security issue .

11 . Moreover, this MM is an embedded system that allows you run tests even your LAN is down.

12 . As we go deeper, dual embedded systems will have large redundancy to handle controls and data transfer.

 

Input Resistance More than 1MΩ
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range 25mV - 5V
  Discharge Min Voltage 2.5V
  Accuracy 0.05percent of FS
  Stability 0.05percent of FS
Current Per Channel Current Range 0.1A - 20A
  Accuracy 0.05percent of FS
  Stability 0.05percent of FS
Power Per Channel Output Power 100W
  Stability 0.1 percent of FS
Charge Charge Mode

Constant Current Charge , Constant Voltage Charge ,

Constant Current and Constant Voltage Charge , CPC

  End Conditon Voltage , Current , Relative Time , Capacity
Discharge Discharge Mode CCD , CPD , CRD
  End Condition Voltage , Current , Relative Time , Capacity
Cycle Loop Measure Range 65535 times
  Max Steps Per Loop 254
  Nested Loop Nested loop Function , Max Support 3 Layers
Protection Software Protection Power - down Data Protection
    Off - line Testing Function
    Setting Protection Condition , Setting Parameter - Low Voltage limit / Upper Voltage limit / Low Current limit / Upper Current limit / Delay Time
  Hardware Protection Additional Anti - reverse Protection Model
Voltage and Current Testing Sample 4 - wire connecting
Noise less than 85dB
Communication Interface Ethernet Port
Per Unit Main Channels Number 8
Dimensions 3U3F , 480 - 730 - 130mm

 

DCIR 18650 Battery Analyzer , Neware Rechargeable Battery Capacity Tester 0