Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
LIR1254 Battery Cycler System

LIR1254 Battery Cycler System

  • High Light

    LIR1254 Battery Cycler System

    ,

    TWS Battery Cycler System

  • Discharge Voltage
    -5V - 5V
  • Record Condition
    Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA
  • Record Frequency
    10Hz
  • Nested Loop
    Nested Loop Function , Max Support 3 Layers
  • Main Channels No.
    8
  • Max Steps Per Loop
    254
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008T-5V20mA-164
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Carton Box
  • Delivery Time
    8 working days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

LIR1254 Battery Cycler System

Neware TWS LIR1254 Cell Battery Cycler System Rechargeable Battery Tester

 

1 . Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny current .

 

 

2 . Testing with the uA current unit is more accurate and more convenient .

 

3 . The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc .

 

4 . Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .

 

5 . dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .

 

6 . The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .

 

7 . Neware 5V10mA / 20mA / 50mA is born for coin cell test , formerly its 5V1mA this modle . Students and researchers in universities and institutes just love this product , its the real star on their mind .

 

Charge Charge Mode CCCharge , CVCharge , CCCVCharge , CPCharge
End Conditon Voltage , Current , Relative Time , Capacity , -deltaV
Discharge Discharge Mode CCD , CPD , CRD
End Condition Voltage , Current , Relative Time , Capacity
Pulse charge CCC , CPC
Discharge CCD , CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function , Max Support 3 Layers
Protection Software Protection Power - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
IP protection level Protection level IP20
Voltage and Current Testing Sample 4 - wire connecting
Database MySQL Database
Per Unit Main Channels No. 8

 

LIR1254 Battery Cycler System