Neware Technology Limited 86--18689201545 Support@battery-cyclers.com
MYSQL Database Battery Cell Cycler 5V10mA Charge Discharge Test

MYSQL Database Battery Cell Cycler 5V10mA Charge Discharge Test

  • High Light

    5V10mA Battery Cell Cycler

    ,

    MYSQL Battery Cell Cycler

    ,

    MYSQL battery charger test

  • Voltage Max
    0V - 5V
  • Current Max
    5uA - 10mA
  • Noise
    Less 85dB
  • Database
    MYSQL
  • Channels No.
    8CH
  • Working Temperature Range
    0 - 40 Degree Celsius
  • Place of Origin
    China
  • Brand Name
    Neware
  • Certification
    CE
  • Model Number
    CT-4008T-5V10mA-164
  • Minimum Order Quantity
    1 Unit
  • Price
    USD negotiation per Unit
  • Packaging Details
    Carton box , 530 - 360 - 130mm
  • Delivery Time
    8 working days
  • Payment Terms
    T/T
  • Supply Ability
    100 Units Per Month

MYSQL Database Battery Cell Cycler 5V10mA Charge Discharge Test

Neware 5V10mA Battery Charge and Discharge Cell Cycle Life Tester

 

 

The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .

 

Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .

 

This 8 Channels Coin Cell Analyzer 5V10mA provides most applications in battery testing fields such as electrode materials research, battery performance test , small - scale battery formation , capability grading , battery pack testing and etc .

20 set of mA Neware battery testers can be put in one rack

 

It mainly focuses on battery research and development instituions and universities .

 

dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .

 

 

 

Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range 0V - 5V
Discharge Min Voltage 0V
Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Current Per Channel Current Range Range1 , 5uA – 1mA Range2 , 1mA – 5mA Range3 , 5mA – 10mA
Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Power Per Channel Output Power 0.25W
Stop current Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA
Stability 0.1percent of FS
Data Recording Record Condition Min Time - 100mS
Min Voltage - 10mV
Min Current - Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA
Record Frequency 10Hz
Charge Charge Mode CCCharge , CVCharge , CCCVCharge , CPCharge
End Conditon Voltage , Current , Relative Time , Capacity , -deltaV
Discharge Discharge Mode CCD , CPD , CRD
End Condition Voltage , Current , Relative Time , Capacity
Pulse charge CCC , CPC
Discharge CCD , CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Voltage and Current Testing Sample 4 - wire connecting
Database MySQL Database
A Means of Communication of Upper Machine TCP / IP Protocol
Communication Interface Ethernet Port

 

 MYSQL Database Battery Cell Cycler 5V10mA Charge Discharge Test 0