• Neware Technology Limited
    Mr. SAVIN Jean-Francois
    We have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
  • Neware Technology Limited
    Prof. Lv Li
    We have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
  • Neware Technology Limited
    Mr. Frank Groen
    Various neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
Contact Person : Neware Support Team
Phone Number : +86-18689201545

5V20A Lithium Battery Cell Testing Equipment Formation Grading

Place of Origin China
Brand Name Neware
Certification CE
Model Number CT-4016-5V20A-NFA
Minimum Order Quantity 1 Unit
Price USD negotiation per Unit
Packaging Details wooden box
Delivery Time 45 word days
Payment Terms T/T
Supply Ability 10 Units Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Voltage Range 0V - 5V Current Range 100mA - 20A
Input Power 2835W Min Voltage Resolution 10mV
Min Current Resolution 40mA Channel Number 16
High Light

5V battery cell testing equipment

,

Formation Grading battery cell testing equipment

,

20A lithium battery testing equipment

Leave a Message
Product Description

Neware Battery Cell Formation and Grading System 5V20A Battery Testing Equipment

 

Battery researchers and scientists , battery manufactures , importers and exporters , you can always choose the most .

 

Recycle Battery Function

If you have recovery battery pack , like Toyota Prius battery pack , generally, each piece has 6 single Ni - MH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter . 

 

Simulation - the Way You Look into Reality

You know battery capacity at at constant current , or power , or load . But the reality is that no the energy is drawn by a constant variable . Your capacity or energy tested under constant conditions can only be a general one , and the cycle life tested such regime can also be largely deviated from reality . To have a better master of reality, simulation is introduced . GSM pulse is of such kind for phone batteries . for EV batteries , Drive Cycle Simulation is used .

 

Driving Cycle Simulation

Driving cycles are used to simulate car fuel economy at different operating conditions . There are many driving schedules or driving cycles that are issued by various agencies or institutes. To simulate EV , you need to convert the speed output into the power consumption or regeneration of the energy storage device installed on the vehicle .

 

Accurate Timing

Most of us are considering the voltage and current accuracies are the all important factors of a battery tester , but actually timing accuracy is of the same importance .

 

Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated . To a general constant current or other constant testing regimes, this effect may not that easy to be observed . 

 

Input Resistance More than 1MΩ
Input Power 15335W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range 25mV - 5V
Discharge Min Voltage 2.5V
Accuracy 0.05 percent of FS
Stability 0.05 percent of FS
Time Current Response Time 20ms
Charge Charge Mode CCCharge , CVCharge , CCCVCharge , CPCharge
End Conditon Voltage , Current , Relative Time , Capacity , -deltaV
Discharge Discharge Mode CCD , CPD , CRD
End Condition Voltage , Current , Relative Time , Capacity
Pulse charge CCC , CPC
Discharge CCD , CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function , Max Support 3 Layers
Protection Software Protection Power - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
IP protection level Protection level IP20
Voltage and Current Testing Sample 4 - wire connecting
A Means of Communication of Upper Machine TCP / IP Protocol
Data Output EXCEL , TXT , Graph
Communication Interface Ethernet Port
Per Unit Main Channels No. 16

 