• Neware Technology Limited
    Mr. SAVIN Jean-Francois
    We have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
  • Neware Technology Limited
    Prof. Lv Li
    We have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
  • Neware Technology Limited
    Mr. Frank Groen
    Various neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
Contact Person : Neware Support Team
Phone Number : +86-18689201545

1000Hz Lithium Ion Battery Charger Tester Analyzer GSM CDMA Support

Place of Origin China
Brand Name Neware
Certification CE
Model Number CT-9008-5V6.5A-SMB
Minimum Order Quantity 1 Unit
Price USD negotiation per Unit
Packaging Details Carton Box , W - D - H , 585 - 575 - 130mm
Delivery Time 20 working days
Payment Terms T/T
Supply Ability 100 Units Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Current Range1 0.12uA - 180uA Current Range2 180uA - 6mA
Current Range3 6mA - 180mA Current Range4 180mA - 6.5A
Voltage Delta U 1mV Current Response Time Less Than 100μS
High Light

CDMA Support Battery Charger Tester Analyzer

,

1000Hz Battery Charger Tester Analyzer

,

GSM Support Lithium Ion Battery Analyzer

Leave a Message
Product Description

Battery Charger Tester Anazlyer for Lithium Ion Battery Measuring
 
The core technologies are improvement on a new height , such as 8channel design , 0.02percent of FS accuracy, 1000Hz data acquisition frequency , multi - range , supporting GSM and CDMA . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .

 

Accuracy 0.02percent of FS , 4 auto - switch output ranges , 400us pulse width, 1000Hz data record frequency , characterized above and even more advanced features , Neware BTS9000 is born to be the most advanced battery testing system , it is the best choice for you to find the future battery material .
 
Neware CT - 9000 is the best ever battery tester from Neware , it came into the market with extremely high accuracy , Amazingly quick hardware response time , high - speed data acquisition frequency and many other industry - proven characteristics , it can tell the subtle difference of all kinds of battery materials , it helps you to find the future battery material and solution . CT - 9000 is mainly designed for Battery research insitutues , universities and laboratories of battery companies.
 
 
GSM TEST / PULSE TEST / DCIR TEST
1 . BTS9000 is based on Neware sixth - generation testing system . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .
 
2 . As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
 
 
A. 1000HZ
We designed and shipped our sophisticated series which is characterized with a max . data acquisition frequency of 1000Hz , a minimum pulse width reaching 400us , an accuracy of 0.02percent of FS and auto multi - current ranges enabled .
 
B. 43,000 Hours - 5 years
Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
 
C. Customers
We supply , cooperate with more than 19000 customers all over the world , ranging from battery manufacturer to research and develop institutes .
 
It characterized with a data acquisition frequency up to 1000Hz , an accuracy of 0.02pecent of FS and a minimum pulse width of 400us - microsecond which can be utilized for GSM or some other rapid pulse tests . Comes to the pulse tests , BTS9000 supports GSM Global System for Mobile Communications , GPRS General Packet Radio Service , CDMA - standby , CDMA - talk Code Division Multiple Access , IDEN Integrated Digital Enhanced Networks , etc.

 

Project index Parameter index
Channel Features Four test range , wide dynamic range , high speed sampling , high precision
Channel Control Mode Independent control
Voltage Per Channel Voltage Range 0 V~5V
Min discharge voltage 0.7 V - 0.5m cable , 5A discharge
Accuracy 0.02percent of FS
Stability 0.005percent of FS
Current Accuracy 0.02 percent of FS
range1 , 36nA
range2 , 1.2uA
range3 , 36uA
range4 , 1.3mA
Stability 0.005 percent of FS

 
1000Hz Lithium Ion Battery Charger Tester Analyzer GSM CDMA Support 0