All Products
-
Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
Contact Person :
Neware Support Team
Phone Number :
+86-18689201545
Keywords [ tws battery cycler system ] match 12 products.
LIR1254 Battery Cycler System
Discharge Voltage: | -5V - 5V |
---|---|
Record Condition: | Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA |
Record Frequency: | 10Hz |
TWS LIR1654 Button Battery Cycler System For Rechargeable Battery
Frequency: | 10Hz |
---|---|
Range1: | 5uA – 1mA |
Range2: | 1mA – 10mA |
3.6V TWS LIR854 Button Cell Battery Cycler System MySQL Database
Stability: | 0.05 Percent Of FS |
---|---|
Stop Condition: | Voltage , Current , Relative Time , Capacity |
Min Voltage: | -5V |
Recovery Battery Capacity Analyzer , IP20 Neware Battery Cycler System
Dimensions: | 3U , 480 - 404 - 130mm |
---|---|
IP Protection Level: | Protection Level IP20 |
Nested Loop: | Nested Loop Function,Max Support 3 Layers |
Nested Loop TWS Battery Cell Tester Charge Discharge Cycler
Dimensions: | 3U , 480 - 404 - 130mm |
---|---|
IP Protection Level: | Protection Level IP20 |
Nested Loop: | Nested Loop Function,Max Support 3 Layers |
TWS Battery Capacity Discharge Tester
Voltage Range: | Charge 25mV - 5V , Discharge 1.5V - 5V |
---|---|
Communication Of Upper Machine: | TCP / IP Protocol |
Channel Current Range: | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
dQ/dV GITT High C Rate Battery Testing System
Discharge: | 2.0V - 5V |
---|---|
Current Range1: | 5mA - 1A |
Current Range2: | 1A - 6A |
LIR1040 Lithium Battery Analyzer , 8CH TWS Battery Capacity Discharge Tester
Loop Measure Range: | 65535 Times |
---|---|
Steps Per Loop: | 254 |
Nested Loop: | Max Support 3 Layers |
TWS 18650 Battery Capacity Tester , 8CH Battery Capacity Analyzer
End Condition: | Voltage , Current , Relative Time , Capacity |
---|---|
Charge Mode: | CCCharge , CVCharge , CCCVCharge , CPCharge |
Discharge Mode: | CCD , CPD , CRD |
CR2450HT Lithium Ion Battery Analyzer
Stability: | 0.05 Percent Of FS |
---|---|
Pulse Width Min: | 500ms |
Min Voltage: | -5V |