Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Right-click the channel display area, if the option is grayed out, user needs to log in first, then corresponding operation can be carried out:

 

For functions that cannot be operated in the right-click menu, hovering mouse cursor over a corresponding position,the corresponding reason will pop up,as shown in figure below.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Choose what items will be shown in the right menu.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Single start: When a “single start” operation is required,the operation is as follows

 

Select the channel to be operated→right-click→“single start”

 

Work step, recording condition, safety protection etc can be set (as shown in figure below).

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

 

Select the channel to input barcode→Right click→“single start” Click barcode management interface to input barcode, as shown in figure below.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Backup Settings interface Operation method→Select the channel to be tested, right click start→click backup setting perform an automatic backup,as shown in figure below:

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Single stopWhen the working steps of single or multiple channels need to be reset, Select single or multiple channels→right click→“single stop”

Start up test by row/layer: If we need to start up tests for more than 1 channel at the same time, say start up tests on a row or a layer.

We can make it by doing as following way.

1. Right click →“unit start”;

2. Here the unit start window popped up, and after we’ve set up the profile path, sample frequency, safety settings, then click ‘ok’button.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

All stop: “all stop” option needs to be executed when all channels test need to be stopped at the same time,operation is as follows: right click in the channel status display area.In this moment, All channels that are being tested will be in a "stop" state.

 

 

Schedule pause: When user wants the channel to stop running automatically after the work step has completed, It can be realized through “Set appointed pause”

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

operation is as follows

1. Select the channel which need appointed pause, (A channel marked with a yellow border),as shown in the figure

2. right click→“set appointed pause”→“Pop up the appointed pause interface”

3. right click→“set appointed pause”→“Pop up the cancel appointed pause interface”

 

After setting the appointment pause, The corresponding channel will display a pause mark “P”, indicates that the current cycle will be paused or the specified cycle will be paused after completion; When the number appears in the right corner of the pause mark,represents the pause after the completion of the current work step or specify pause after the work step is completed,the number represents the serial number of the work step.When the pause Settings need to be unset,select the option to cancel the appointment pause in the right-click menu.the mark of appointed pause on the channel will disappear;After the current work step or cycle is completed “pause”will appear on the channel.

 

 

Continue/resume test Sometimes you did continue/resume operations on the running tests to protect the data from being loss or due to some other reasons. And after that, you can to continue/resume the tests, then you can use this function. Operation: Select the channels need to be ‘continue’, right click and choose ’continue’, then the paused tests will resume and go on.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

Note: Stop and continue can only be used on channels ongoing, for channels Finished/completed, this function makes no sense.

 

 

Jump: When the channel is executing a working step,the current work step can jump to the target work step,This operation maintains the normal continuation of the test data method:

1. Double click the working step,when the working step background turns yellow, it is selected.

2. In the “Jump”interfaces,Fill the required working step number in, as shown in figure below:

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

 

Channels move Function: Migration of working step parameters and test data from one unfinished test channel to another completed test channel to continue testing,the purpose is to prevent the failure of this test due to channel damage. operational approach:

1. Select both channels(test channel,Target channel after migration)

2. Right click→“channels move”;the target channel is not in the working state

Note:this function only support for BTS80 and above BTS types

 

 

Reset steps: When the user needs to modify the working step or parameters of the running channel, it can be achieved by resetting the working step

Operation method:

1. Choose the running channel need to modify the test profiles;

2. Right click and choose ‘reset step, then the test profile editor will show up as screenshot below.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Reset barcode: Once the tests already started but operators find the bar-codes were wrong, then they

Neware BTS 8.0 user manual 67 can use bar-code rest to modify the barcodes. Operation steps: 1) Choose the barcodes/channels need to be modified, right click and choose “bar-code rest”, the start test window will pop up, you can reenter or modify the barcodes here.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Lock/unlock channels

1. For some channels which are running important tests and you just don’t want others to touch them incidentally, then lock them up would be the best option here. Right click on the channels you want to lock and select ‘chnl locking’, then the channels will be locked with an icon . Pretty useful, right?

2. If you want to unlock the channels, just need to right click on the channels and choose ‘channel unlock’, then it will be unlocked.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Choose the channels need to unlock.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Reset alarm

1. Some channels were showing red exclamation mark due to safety settings triggered, in this kind of case, if you need to clear the warning, then right click on the channels and choose ‘reset alarm’, then the warning message will be gone.

 

2. If there are more than one channel were in warning status and you want to clear them all, then please right click on the mid machine ID, and choose ‘reset alarm’, then you can clear all the warning messages on all the channels under this mid machine.

 

Channels copy Function: When the channel ranges are the same, copy the step parameters of one channel to another or multiple channels. Operation method:

1. Select the target channel;

2. Right-click → "Channel Copy" to enter the channel copy interface, as shown in the figure below;

3. Click "Select Channel" in the lower right corner of the interface to enter the channel selection interface;

4. Select the channel number to be copied.

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

Clear mark(reset channels)

Some functions can only be operated when the channel is completed. For protected or stopped channels, use the clear flag to change the channel status to completed. Operation method:

1. Select the target channel in the channel area

2. Right click "clear mark" .

 

Units settings: According to the different test purposes of users, set the corresponding unit parameters to provide a flexible and simple setting platform.

Operation method: Right-click on the channel --> "Unit customization", select the unit to be set --> "OK", at this time, the data unit in the test data has been displayed according to the unit parameter set by the user, as shown in the following figure:

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

View log: The BTS logs are included local logs and equipment logs. The local logs are user operations recorded by the client. The equipment logs are the channel test status changes recorded by the central computer and abnormal and prompt information during the test.

Operation method: Select the channel, right-click --> Log, and the log list will open as shown in the figure below:

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

 

 

For local logs, you can double-click to view further information. For example, reset the mapping to view the mapping information before and after mapping, as shown in the following figure:

latest company news about Neware Battery Test Equipment BTSClient8.0 Right Click the Channel Interface

Double click to see log details