Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
5V12A Cylinder Battery Cycle Tester
Voltage Range | -5V - 5V | Stable | 0.1percent Of FS |
---|---|---|---|
Voltage And Current Testing Sample | 4 - Wire Connecting | Database | MySQL Database |
Current Response Time | 1ms Above | Min Pulse Width | 500ms Above |
High Light | Cylinder Battery Cycle Tester,5V12A Battery Cycle Tester |
Neware 5V12A Micro Battery Cycle Test Equipment Cylinder Battery Analyzer
1 . For a 3000mAh cell battery , people want to charge it at 6000mA - 2C or even 9000mA - 3C current . And in some labs , researchers are trying 10C or even higher C - Rate charge or discharge . In this situation , 5V12A is the very rising star for both battery manufactures and researchers .
2 . To meet the various requirements adopted in advanced battery research , our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy , and can be fitted with additional hardware to provide a number of optional features and capabilities .
3 . 5V12A Battery Testing System is mainly used for testing polymer batteries , cylindrical batteries and super capacitors . The test of polymer batteries and super capacitors need Neware special accessories .
4 . Neware 5V12A is the most popular battery tester ever , more than 50 percent customers would choose this model as their main products .
5 . For customers who came across Neware the first time , 5V12A is also strongly suggested as their tryout demo machine . Neware 5126A is powerful , reliable , it works on the very popular coin cell , cylindrical cell and prismatic cells , etc . It can be used for battery formation and grading , cycle - life test , performance and so on .
6 . Nowadays battery capacity density becomes higher and higher , thats the trend of this whole energy industry , people need smaller dimension battery to contain more energy . New technology and upgraded producing process make this idea come into reality . Of course , high C - Rate charge - Quick charge is another reason for higher current testers become more popular than before .
7 . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Discharge Min Voltage | 1.5V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Time | Current Response Time | 1ms |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time |