Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
8 CH Lithium Ion Battery Analyzer
Channel Control Mode | Independent Control | Minimum Time Interval | 100ms |
---|---|---|---|
Record Condition | Voltage Interval - 10mV | End Condition | Voltage , Current , Relative Time , Capacity |
Loop Measure Range | 1 - 65535 | Warranty | 1 Year |
High Light | 5V6A lithium ion battery analyzer,8 CH lithium ion battery analyzer |
Neware 8 CH Battery Testing Equipment 5V6A Lithium Ion Battery Analyzer
A . Neware 5V6A is the most popular battery tester ever , more than 50 percent customers would choose this model as their main products .
B . For customers who came across Neware the first time , 5V6A is also strongly suggested as their tryout demo machine .
C . It can be used for battery formation and grading , cycle - life test , performance and so on .
D . Higher range 100mA - 3A - 6A , makes it the best choice for cycle - life test and C - Rate test on 3C battery cells . Lower range 0.5mA - 100mA - 1A , makes 5V6A great for small pouch , coin cell and small battery test .
E . Nowadays battery capacity density becomes higher and higher , thats the trend of this whole energy industry , people need smaller dimension battery to contain more energy .
F . Of course , high C - Rate charge - Quick charge is another reason for higher current testers become more popular than before .
G . For a 3000mAh cell battery , people want to charge it at 6000mA - 2C or even 9000mA - 3C current . And in some labs , researchers are trying 10C or even higher C - Rate charge or discharge . In this situation , 5V12A is the very rising star for both battery manufactures and researchers .
H . 5V6A Battery Testing System is mainly used for testing polymer batteries , cylindrical batteries and super capacitors . The test of polymer batteries and super capacitors need Neware special accessories . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Discharge Min Voltage | 1.5V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 3A Range3 , 3A - 6A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Power | Per Channel Output Power | 30W |
Stop current | Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | |
Stability | 0.1percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers |