Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
60V60A Channel Parallel Regenerative Battery Pack Test System CE Listed
Charge Voltage | 0.3V - 60V | Charge Current | 0.3A - 60A |
---|---|---|---|
Accuracy | Positive And Negative 0.05 Percent Of FS | Stability | Positive And Negative 0.1 Percent Of FS |
Current Response Time | Less Than 3ms 10 Percent To 90 Percent | Cycle Times | 65535 |
Steps Limited | 254 | Database | MySQL |
High Light | CE Regenerative Battery Pack Test System,60V60A Regenerative Battery Pack Test System,Channel Parallel battery pack test equipment |
Neware Regenerative Battery Pack Test Equipment 60V60A with Channel Parallel
CE - 6000 series regenerative battery module pack tester designed for secondary battery charge / discharge test , specialized in testing high power module / pack battery . It has a high dynamic response speed , high accuracy . Also , the regenerative function is included to greatly reduce power consumption during the discharge test .
CAN Bus Decoder
To handle data exchange with the BMS installed on battery module or pack , Neware 6000 is also a CANBUS decoder with decode the signals from BMS . And these valuable data could be applied for further computing like used as stopping or protection conditions .
You can config which frame of CANBus data is for what use manually . Data also can be easily processed with the DBC file imported .
Simulation - the Way You Look into Reality
You know battery capacity at at constant current , or power , or load . But the reality is that no the energy is drawn by a constant variable . Your capacity or energy tested under constant conditions can only be a general one , and the cycle life tested such regime can also be largely deviated from reality . To have a better master of reality, simulation is introduced . GSM pulse is of such kind for phone batteries . for EV batteries , Drive Cycle Simulation is used .
Driving Cycle Simulation
Driving cycles are used to simulate car fuel economy at different operating conditions . There are many driving schedules or driving cycles that are issued by various agencies or institutes. To simulate EV , you need to convert the speed output into the power consumption or regeneration of the energy storage device installed on the vehicle .
Charge |
Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | |
Discharge |
Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
Pulse |
Charge | Constant current , Constant power |
Discharge | Constant current , Constant power | |
Min pulse width | 100ms | |
Pulse counts | Each pulse step supports 32 different pulses | |
Chg and Dschg switch | Supported | |
Cut - off condition | Voltage , Time | |
Simulated Condition | Charge modes | Constant current , Constant power |
Discharge modes | Constant current , Constant power | |
Cut - off condition | Time , Line Number | |
Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
Limit step number | 1 million | |
Protection | Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc. | |
Protection grade | IP20 | |
Channel parallel |
supported , Parallel channels do not support pulse and simulation testing |
|
Energy feedback | The discharge energy can be fed back to the power grid |
Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
Channels control mode | Independent control |
Noise | ≤65dB |