• Neware Technology Limited
    Mr. SAVIN Jean-Francois
    We have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
  • Neware Technology Limited
    Prof. Lv Li
    We have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
  • Neware Technology Limited
    Mr. Frank Groen
    Various neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
Contact Person : Neware Support Team
Phone Number : +86-18689201545

1000Hz Lithium Battery Testing Equipment

Place of Origin China
Brand Name Neware
Certification CE
Model Number CT-9004-5V5A-G4
Minimum Order Quantity 1 Unit
Price USD negotiation per Unit
Packaging Details Carton Box , 585 - 575 - 130mm
Delivery Time 20 working days
Payment Terms T/T
Supply Ability 100 Units Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Record Condition Time , Voltage , Current Min Discharge Voltage 0.7 V
Per Channel Output Power 25W Record Frequency 1000Hz Continuous Charge / Discharge Mode / GSM Pulse Mode
DCIR Support For The Calculation Of The Point Of The DCIR Software Protection Off-line Testing Function
High Light

1000Hz lithium battery testing equipment

,

25W lithium battery testing equipment

Leave a Message
Product Description

Neware Lithium Ion Battery Material Research Test System 1000Hz Frequency

 

1 . Accuracy 0.02percent of FS , 4 auto - switch output ranges , 400us pulse width, 1000Hz data record frequency , characterized above and even more advanced features , Neware BTS9000 is born to be the most advanced battery testing system , it is the best choice for you to find the future battery material .

 

2 . The core technologies are improvement on a new height , such as 8channel design , 0.02percent of FS accuracy, 1000Hz data acquisition frequency , multi - range , supporting GSM and CDMA . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .

 

3 . Neware CT - 9000 is the best ever battery tester from Neware , it came into the market with extremely high accuracy , Amazingly quick hardware response time , high - speed data acquisition frequency and many other industry - proven characteristics , it can tell the subtle difference of all kinds of battery materials , it helps you to find the future battery material and solution . CT - 9000 is mainly designed for Battery research insitutues , universities and laboratories of battery companies.

4 . CT - 9004 , as our latest battery testing system , brings you up - to- date , sophisticated hardware technology and brand - new software experience . Its characterized with a maximum data acquisition frequency of 1000Hz , 4 automated - switch output ranges , 0.02percent accuracy and a minimum pulse width of 400μs .
 
5 . BTS9000 is based on Neware sixth - generation testing system . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .


6 . As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
 

Current Current range range1 , 0.1uA -150uA
range2 , 140uA - 5mA
range3 , 4.5mA - 150mA
range4 , 140mA - 5A
Accuracy 0.02 percent of FS
range1 , 30nA
range2 , 1uA
range3 , 30uA
range4 , 1mA
Stability 0.005 percent of FS
Data Recording Record Condition Time delta T- more than 1ms
Voltage delta U - more than 1mV
Current delta I - more than 100nA
Record Frequency 1000Hz Continuous Charge / Discharge Mode / GSM Pulse Mode;
Discharge Discharge Mode CCD / CPD / CRD / Pulse Discharge
End Condition Voltage , Current , Relative Time , Capacity
Pulse mode Charge CC , CP mode
Discharge CC , CP mode
Min pulse width 400μs
Pulse number Single pulse working step supports 16 different pulse segments
End Condition Voltage , Relative Time
Protection Software Protection Power - down Data Protection
Off - line Testing Function
Setting Protection Condition , Setting Parameter - Low Voltage limit , Upper Voltage limit - Low Current limit - Upper Current limit - Delay Time
Database MySQL Database
A Means of Communication of Upper Machine TCP / IP Protocol , 100M Ethernet
Data Output EXCEL2003 , 2010 , TXT

 