-
Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
Aircraft Coins Battery Cell Cycler 8 Channels MySQL Database
Discharge Voltage | 0V - 5V | Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 5mA Range3 , 5mA – 10mA |
---|---|---|---|
Accuracy | 0.05 Percent Of FS | Input Power | 25W |
Pulse Width | 500ms | Pulse End Condition | Voltage , Test Time |
Loop Measure Range | 65535 | End Conditon | 254 |
High Light | Coins Battery Cell Cycler,aircraft Battery Cell Cycler,8 Channels aircraft battery capacity tester |
Neware Coins Battery Cell Cycler Battery Material Testing System
1 . dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .
2 . Testing with the uA current unit is more accurate and more convenient .
The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .
3 . Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level . Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny current .
4 . This 8 Channels Coin Cell Analyzer 5V10mA provides most applications in battery testing fields such as electrode materials research, battery performance test , small - scale battery formation , capability grading , battery pack testing and etc .
20 set of mA Neware battery testers can be put in one rack
5 . CT-4000 Multi Range mA Battery Testing System , characterized with 0.05 percent of FS accuracy and down to uA capability , enables users to perform DCIR tests , dQ / dV and other basic tests on three - electrode system . It mainly focuses on battery research and development instituions and universities .
6 . Neware 5V10mA / 20mA / 50mA is born for coin cell test , formerly its 5V1mA this modle . Students and researchers in universities and institutes just love this product , its the real star on their mind .
7 . The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc . The newest 5V10mA/20mA/50mA is much more accurate and stable . Many students think Neware testers help them a lot in their battery research and paper work .
resolution | AD 16bit , DA 16bit | |
Input Resistance | More than 1MΩ | |
Voltage | Per Channel Voltage Range | 0V - 5V |
Discharge Min Voltage | 0V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 5mA Range3 , 5mA – 10mA |
Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 10mA Range3 , 10mA – 20mA | |
Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 25mA Range3 , 25mA – 50mA | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Voltage and Current Testing Sample | 4 - wire connecting | |
Noise | Less than 85dB | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP / IP Protocol | |
Data Output | EXCEL , TXT , Graph | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 8 | |
Dimensions | 3U , 480 – 404 - 130mm |