Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
5V12A Battery Capacity Discharge Tester Pulse Discharge Analyzer
Voltage Range | 1.5V - 5V | Channel Current Range | 5mA - 6A - 12A |
---|---|---|---|
Min Current Record Condition | 2mA - 12mA - 24mA | Noise | Less Than 85dB |
Data Output | EXCEL , TXT | Database | MYSQL |
High Light | Battery Capacity Discharge Tester Analyzer,Pulse Battery Capacity Discharge Tester,5V12A lithium ion battery analyzer |
Neware 5V12A Battery Capacity Discharge Test System Pulse Discharge Analyzer
Recycle Battery Function
1 . If you have recovery battery pack , like Toyota Prius battery pack - generally , each piece has 6 single NiMH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc .
2 . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter .
Voltage and Current - the Very Essential
1 . The accuracies of Voltage and / or current may fundamentally affect the results come from a test . Thats why accuracies of voltage and current are so important to a battery tester .
2 . Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .
3 . A measurement system can be accurate but not precise , precise but not accurate , neither , or both . Neware battery testers provide good prrecision meanwhile .
4 . To get an overall performance of a measurement system , Measurement system analysis MSA is usually introduced for the study .
20ms Response Time
1 . This fast response time will meet rapidly changing power requirements
2 . Flexible Integration of Hardware and Data Management
3 . BTS 4000 functions also as the core part of auto formation and grading system .
4 . With its structural data system , testing data can be analysed , summarized , managed and utilized by our extended program or customers own data and logic server .
Input Power | 425W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Accuracy | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time |