Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
18650 Battery Capacity Discharge Tester 6 Single NiMH Cell Echelon Utilization Recovery
Warranty | 1 Year | Voltage Range | 1.5V - 5V |
---|---|---|---|
Max Steps Per Loop | 255 | Data Output | EXCEL , Graph |
Dimensions | 3U , 480mm – 330mm - 180mm | Channel Control Mode | Independent |
High Light | 18650 Battery Capacity Discharge Tester,NiMH Cell Battery Capacity Discharge Tester,NiMH Cell 18650 discharge tester |
Neware Battery Capacity Discharge Tester Echelon Utilization Battery Recovery
a . BTS4000 is very possibly the correct choice for you to get to know Neware and her battery test products better .
Till year 2017 , 90percent new customers of Neware would choose BTS4000 as a starting point , its really the time - proven and reliable choice .
b . Due to the rapid data acquisition frequency , BTS4000 could be applied to super capacitor or EDLC - Electronic Double Layer Capacitor test . Through our advanced software , the capacitance , DCIR - Direct Current Internal Resistance could be easily calculated .
c . Higher Accuracy . More Cost - effective . We believe it can improve your battery test .
d . Neware Battery Charge and Discharge Test System , ranging from uA single cell applications up to 1MW packs , is a high precision system designed specifically for testing lithium ion battery cells , modules , packs and capacitors . It is suitable for product development , quality control , and helpful to characteristic research , cycle life testing , product screening , and quality assessment .
Recycle Battery Function
a . If you have recovery battery pack , like Toyota Prius battery pack - generally , each piece has 6 single NiMH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter .
Voltage and Current - the Very Essential
b . The accuracies of Voltage and / or current may fundamentally affect the results come from a test . Thats why accuracies of voltage and current are so important to a battery tester .
c . Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .
d . A measurement system can be accurate but not precise , precise but not accurate , neither , or both . Neware battery testers provide good prrecision meanwhile . To get an overall performance of a measurement system , Measurement system analysis MSA is usually introduced for the study .
Input Power | 425W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Accuracy | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
Per Unit Main Channels No. | 8 | |
Dimensions | 3U , 480 – 330 - 180mm |