18650 Cylindrical Battery Cycle Tester Neware 8 channel Polymer Battery Tester
1 . Specialized in testing 18650 / 26650 / 21700 / 32650 Cylindrical Battery , Pouch Battery , Super Capacitor , etc .
2 . Neware 5V12A is the most popular battery tester ever , more than 50 percent customers would choose this model as their main products .
3 . Nowadays battery capacity density becomes higher and higher , thats the trend of this whole energy industry , people need smaller dimension battery to contain more energy . New technology and upgraded producing process make this idea come into reality . Of course , high C - Rate charge - Quick charge is another reason for higher current testers become more popular than before .
4 . To meet the various requirements adopted in advanced battery research , our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy , and can be fitted with additional hardware to provide a number of optional features and capabilities .
5 . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Discharge Min Voltage | 1.5V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Power | Per Channel Output Power | 30W |
Stop current | Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | |
Stability | 0.1percent of FS | |
Time | Current Response Time | 1ms |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers |