Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
10Hz Button Lithium Ion Battery Analyzer 5V 50mA
Current Range 1 | 5μA - 1mA | Current Range 2 | 1mA - 25mA |
---|---|---|---|
Current Range 3 | 25mA - 50mA | Delta U | 1mV |
Per Channel Power | 0.25W | Frequency | 10Hz |
High Light | 10Hz Lithium Ion Battery Analyzer,Lithium Ion Battery Analyzer 5V 50mA,5V 50mA Lithium Battery Capacity Tester |
Coin Cells Lithium Ion Battery Analyzer Button Battery Capacity Tester
The system is oriented to button batteries, super capacitors , three electrodes for testing, mainly for small current batteries , the smallest can reach uA test unit , the system covers DCIR test , pulse simulation test, rate charge and discharge test , cycle life test , etc .
It is equipped with dQ/dV differential capacity curve function .
The use of this function can reduce manual calculations and save personnel data investigation time . It is a highly practical device that can meet the needs of universities and research institutions testing needs .
Charge | Charge Mode |
Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse mode | Charge | CC , CP mode |
Discharge | CC , CP mode | |
Pulse number | Single pulse working step supports 16 different pulse segments | |
End Condition | Voltage , Relative Time | |
DCIR | Support for the calculation of the point of the DCIR | |
Cycle | Loop Measure Range | 65535 |
Max Steps Per Loop | 255 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit , Upper Voltage limit - Low Current limit - Upper Current limit - Delay Time | ||
Database | MySQL Database |