Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
HMI Operation 8CH 60V 20A Automotive Battery Tester
Voltage | 3V - 60V | Current | 0.1A - 20A |
---|---|---|---|
Input Power | 11.3 KW | Data Output Mode | EXCEL, TXT, Curve, Chart |
Interface | Net Port | Channel Number | 8 |
High Light | 60V 20A Automotive Battery Tester,8CH Automotive Battery Tester,60V 20A Car Battery Testing Equipment |
8CH 60V20A Automotive Electric Trike Battery Tester and Electric Tricycle Battery Tester
Features(some features required a customization):
1. High-performance charge/discharge test platform developed for high-power battery modules(or packages).
2. Adopting AC/DC,DC/DC Dual-level high frequency module design, combined with low temperature drift, high-performance C. multi-channel 24-bit analog-to-digital conversion chip(ADC) to achieve higher stabilize accuracy.
3. High-level power density system with multi-channel integration and capable for energy recovering.
4. HMI operation, smart calibration.
5. Multiple adaption for BMS, supports the same/different charge and discharge ports, relay/MOSBMS solution, independent CAN and RS485 communication expansion, and DBC configuration.
6. Remote control available for host computer through Ethernet, channels parallel, pulse and driving simulation available.
7. Man-computer integration interface design, minimized system for easy-understand operating, customized setting available, automatic reminder for termly calibration.
Introduction:
1. Power battery simulation , C - rate test .
2. Life cycle test.
3. Power test , capacity test , energy density test.
4. Power battery virtual distribution : charge / discharge curve fitting , battery consistency test and evaluation.
5. High rate charge / discharge test .
6. Power battery , serial energy - storage battery module test : single cell voltage , Single cell temperature monitoring ( high - voltage equipment ).
Charge |
Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power | |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | ||
Discharge |
Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance | |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
Pulse |
Charge | Constant current , Constant power |
Discharge | Constant current , Constant power | |
Min pulse width | 100ms | |
Pulse counts | Each pulse step supports 32 different pulses | |
Chg and Dschg switch | Supported | |
Cut-off condition | Voltage, Time | |
Simulated Condition | Charge mode | Constant current , Constant power |
Discharge modes | Constant current , Constant power | |
Cut-off condition | Time , Line Number | |
Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
Limit step number | 1 million | |
Cycle |
Max cycles | 65535 |
Max steps | 254 | |
Cycle nest | Nested loop Function,Max Support 3 Layers | |
Charge and discharge efficifency | more than 90 percent | |
Protection | Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc . | |
Protection grade | IP20 | |
Channel parallel |
Supported , parallel channels do not support pulse and simulation testing |
|
Energy feedback | The discharge energy can be fed back to the power grid |
Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure |
Channels control mode | Independent control |
Noise | less than 65dB |
Database | MySQL |
Communication | TCP / IP |
Operating system | Windows 7 / 10 64bit |
Data export | EXCEL , TXT |
Min. disk drive | 500GB |
Communication port | Ethernet port |
Communication port | CAN communication module support the communication with BMS to obtain the single voltage and temperature in BMS |