Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
TCP IP 750V 200A Energy Storage Battery Life Cycle Tester
Voltage | 10V - 750V | Current | 1.0A - 200A |
---|---|---|---|
Input Power | 333.3 KW | Input Power Wiring Method | Three Phase Four Wire System |
Interface | TCP IP | Overall System Efficiency ( Max ) | 90 Percent |
High Light | 750V 200A Battery Life Cycle Tester,TCP IP Battery Life Cycle Tester,750V 200A Battery Charge Discharge Tester |
Energy Storage System Battery Pack Cycle Life Testing System 750V200A Charger Equipment
Neware offers after-sales service with certified technicians to train the users for operation, maintenance, etc.
Technical supports:
1. Fundamental operation training.
2. Training for equipment LAN set up and power supply installation.
3. Basic equipment maintenance training.
4. Software operational training: Installation, upgrading, test steps editing, data backup, data analysis and processing, and data export, etc.
5. Training for safety operation.
6. Hardware maintenance training , basic hardware troubleshooting training.
7. Basic software troubleshooting training.
8. Technical questions can be answered by Neware after-sales agent.
Features(some features required a customization):
A. High-performance charge/discharge test platform developed for high-power battery modules(or packages).
B. Adopting AC/DC,DC/DC Dual-level high frequency module design, combined with low temperature drift, high-performance C. multi-channel 24-bit analog-to-digital conversion chip(ADC) to achieve higher stabilize accuracy.
D. High-level power density system with multi-channel integration and capable for energy recovering.
E. HMI operation, smart calibration.
F. Multiple adaption for BMS, supports the same/different charge and discharge ports, relay/MOSBMS solution, independent CAN and RS485 communication expansion, and DBC configuration.
G. Remote control available for host computer through Ethernet, channels parallel, pulse and driving simulation available.
H. Man-computer integration interface design, minimized system for easy-understand operating, customized setting available, automatic reminder for termly calibration.
Charge |
Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power | |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | ||
Discharge |
Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance | |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
Pulse |
Charge | Constant current , Constant power |
Discharge | Constant current , Constant power | |
Min pulse width | 100ms | |
Pulse counts | Each pulse step supports 32 different pulses | |
Chg and Dschg switch | Supported | |
Cut-off condition | Voltage, Time | |
Cycle |
Max cycles | 65535 |
Max steps | 254 | |
Cycle nest | Nested loop Function,Max Support 3 Layers |
Channels control mode | Independent control |
Noise | less than 65dB |
Database | MySQL |
Communication | TCP / IP |
Operating system | Windows 7 / 10 64bit |
Data export | EXCEL , TXT |
Min. disk drive | 500GB |
Communication port | Ethernet port |
Communication port | CAN communication module support the communication with BMS to obtain the single voltage and temperature in BMS |