Battery Cycle Tester
-
Battery Cell Cycler
-
Battery Cycler System
-
Lithium Ion Battery Analyzer
-
Battery Capacity Discharge Tester
-
18650 Battery Charger Capacity Tester
-
8 Channel Battery Analyzer
-
Battery Cell Tester
-
Regenerative Battery Pack Test System
-
Neware Battery Test System
-
EV Battery Testing Equipment
-
Battery Grading System
-
Battery Test Chamber
-
Mr. SAVIN Jean-FrancoisWe have been using Neware benches for testing our primary cells and batteries for several years. We are quite satisfied about the quality of this type of equipment and we find always good and very reactive feedback from their after-sales service to help us in specific case.
-
Prof. Lv LiWe have been using Neware battery testing system for many years. We are focused on different electrochemical tests of lithium-ion batteries. The Neware machine is easy to be used and the program is easy to set. We have conducted charge-discharge cycling for more than 5000 cycles and the machine showed very good stability, which helped us to obtain
-
Mr. Frank GroenVarious neware testing systems have been equipped our laboratory for years and serves very good. We use them for many kinds of tests. Easy to handle the tests and data is well organized for our reporting work. The most important thing is the measurement and control are quite accurate and reliable.
MYSQL Database Battery Cell Cycler 5V10mA Charge Discharge Test
Voltage Max | 0V - 5V | Current Max | 5uA - 10mA |
---|---|---|---|
Noise | Less 85dB | Database | MYSQL |
Channels No. | 8CH | Working Temperature Range | 0 - 40 Degree Celsius |
High Light | 5V10mA Battery Cell Cycler,MYSQL Battery Cell Cycler,MYSQL battery charger test |
Neware 5V10mA Battery Charge and Discharge Cell Cycle Life Tester
The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .
Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .
This 8 Channels Coin Cell Analyzer 5V10mA provides most applications in battery testing fields such as electrode materials research, battery performance test , small - scale battery formation , capability grading , battery pack testing and etc .
20 set of mA Neware battery testers can be put in one rack
It mainly focuses on battery research and development instituions and universities .
dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 0V - 5V |
Discharge Min Voltage | 0V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 5mA Range3 , 5mA – 10mA |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Power | Per Channel Output Power | 0.25W |
Stop current | Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA | |
Stability | 0.1percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Voltage and Current Testing Sample | 4 - wire connecting | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP / IP Protocol | |
Communication Interface | Ethernet Port |